The Spi-Cell Sorter™ sorts photovoltaic cells according to their electrical performance, tested under simulated sunlight. A pulsed xenon lamp with an optical filter provides a close match to the Air Mass 1.5 Global solar spectrum. The spectrum meets the highest International and ASTM specifications (ASTM E927 Class A). The system features automatic cell handling of coinstacked cells and sorts the tested cells into ten output bins.
A computer with user-friendly software adjusts the lamp intensity, controls the measurement process and cell handling, and acquires cell performance data. The data, as a full I-V curve, allows sorting by a variety of selectable criteria. The computer plots the I-V curve and displays a variety of cell characteristics. Curves and data can be printed and stored on disk.
Maximum Solar Cell Dimensions |
210mm x 210mm (8 in. x 8 in.) |
Source |
1 kW xenon arc lamp Filtered to AM1.5 Global spectrum (ASTM E927) Intensity range: 70 to 110 mW/cm² Lamp lifetime: 1000 hrs (typical) |
Illumination Uniformity |
±2% over 156mm x 156mm area ±3% over 210mm x 210mm area |
| Nominal Throughput | 1000 cells/hour |
Measurement Range |
Voltage: 0-5 V |
Resolution |
Voltage: 16 bit (full scale) |
Equipment Dimensions (excluding computer and water chiller systems) |
Width: 345 cm (136 in.) Depth: 191 cm (70 in.) Height: 196 cm (77 in.) |
Equipment Net Weight |
910 kg (2000 lbs) |
Utilities Requirements |
Electricity: 200 - 240 VAC, 30 A, 50/60 Hz, single phase Compressed air: 550 kPa (80 psi) |
Certifications |
|
|